How can I measure capacitance of ceramic capacitors?

Capacitance of ceramic capacitors is measured using measurement instruments such as a LCR meter (measurement principle is here.) and an impedance analyzer.

In our company, the nominal capacitance of ceramic capacitors is measured under following conditions.
(Measurement conditions are also described on the reliability data page in the catalog. Catalogs are here.)

Class 1 Class 2
Standard High Frequency Type C ≤ 10uF C > 10uF
Preconditioning None Thermal treatment (at 150℃ for 1hr) (*2)
Measuring frequency 1MHz±10% 1kHz±10% 120±10Hz
Measuring voltage (*1) 0.5 to 5Vrms 1±0.2Vrms 0.5±0.1Vrms
Bias application None

*1 The figures indicate typical specifications. Please refer to individual specifications in detail.
*2 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150+0/-10℃ for an hour and kept at room temperature for 24±2hours.

Note that capacitance changes by frequency, temperature, voltage and so on.

Please refer to individual specifications about measurement instruments and conditions of each product.