Capacitance of ceramic capacitors changes by temperature,
voltage, frequency, aging and so on. Nominal
capacitance is measured under
conditions described in the catalog. If you measure the capacitance
under the different condition, the result is not always correspond to nominal
capacitance. About our products, you can confirm the
capacitance change by temperature, voltage and frequency in
TY-COMPAS.
Also, the characteristics of used jigs is contained in the measurement result. Therefore, you must
remove the influence of measurement jigs to get accurate capacitance.
Please refer to the manufacturer's manual for the method of compensation.